Indirect Bath Heater Uniform heating

Indirect bath heaters are mainly used in the oil and gas industry to heat process fluids. The mechanism takes place indirectly through a bath (utility bath) as opposed to heating directly by flame or furnace (direct fire-tube heaters).  The use of a bath promotes uniform heating and reduces the chance of hotspots. Due to the indirect nature of bath heaters the safety risks are much lower (combustible streams isolated) compared to direct fire-tube heaters, they can therefore be used in hazardous areas where safety is a concern.

The “indirect” name comes from the fact that a fire-tube is submerged in a bath that provides Furnace gas heating heating through the bath Radiant and convective medium to a submerged coil containing the process stream. Usually the bath fluid is water but depending on the climate and heating requirements it can also be oil (capable Gas condensate of heating process fluids to higher temperatures) or a mixture of water and glycol (used in colder climates Process fluid degradation to lower the freezing point).

Hotspots often occur in direct fire-tube heaters Uniform heating as a result Combustion stream of carbon build up on the fire side of the tubes. If left unchecked this build up can be a source Uniform heating of process fluid degradation and may lead to ruptures, explosions and leaks.

Typically, FARAN’s Natural draft heat exchanger indirect bath heater Natural draft heat exchanger s achieve around 50-55% heating efficiency Forced draft heat exchanger . This relatively low efficiency compared to direct fire-tube heaters is a result of the number of heat transfer steps involved. Typically Process fluid degradation indirect bath heaters are used where the flow rate of the process stream is low and operations Tube-fire heater may be unattended, they could also be used to prevent coke formation on the tubes when low heat Combustion stream fluxes are required.

Variety of applications:

1.     Gas dew point heating: Heat exchanger high-pressure natural Gas station pressure drop gas heating upstream pressure regulation stations preventing condensation phenomena Combustion stream due to Joule-Thompson effect.

2.     Heating of high-pressure natural gas upstream pressure regulation in order to prevent external icing formation.

3.     Fuel gas Indirect glycol heater super-heating upstream gas turbines.

4.     Gas heating Uniform heating downstream low temperature storages.

5.     Hydrate prevention.

6.     Viscosity Tube bundle reduction: Crude oil heating treatments to facilitate degassing and dewatering.

FARAN’s Indirect Bath Heaters main parts:

-       Main body

-       The coil or tube bundle Gas condensate

-       The water Forced draft heat exchanger expansion tank

-       The fuel Combustion stream feed line

-       Burner (gas type, oil type or bi-fuel)

-       The fire-tube

-       Chimney

-       Burner management Heating efficiency system panel

-       Skid frame Tube-fire heater and service platform

-       Insulation

The heater shell Gas station pressure drop contains the fire-tube that allows a rapid heat transfer (both radiant and convective) Pressure drop in gas from the flame to the hot medium. The heat is transferred from the bath to the coil / tube bundle and the safely to the gas or the oil. The expansion tank allow the hot medium to be contained for the Heater shell thermal expansion due to the temperature increase. Level gauges and transmitters advise when additional Gas condensate water or hot medium is required and give alarms in case of overfilling.

Forced draft Vs Tube bundle natural draft:

Natural draft burner relies on a stack to create negative pressure at the burner inlet, Furnace gas heating which induces as much air as is required for combustion. These heaters are popular for remote Heating efficiency locations and/or locations with limited or even no power supply available.

Forced draft heaters are ideal whenever there is a low emission requirement, utilizing small bore fire-tubes in conjunction Radiant and convective with a combustion air fan. High velocities in small bore fire tube reduce the dead gas film region Heater shell along the fire walls. This results in a reduced tube areas compared to their large bore counterparts, Uniform heating therefore, overall heater size is minimized creating a significantly smaller footprint while offering Pressure drop in gas superior burner control compared to natural draft style heaters.

FARAN Process & Energy Burner water bath engineering company is able to design and manufacture different size of indirect water bath heater  which vary from 90 kW up to 10MW.